UPS battery runtime calculator

See how long a battery bank keeps your tower or router up through a power cut, or the capacity a target runtime needs. Nothing you type is sent anywhere.

W
Ah
%
%
h
Estimated runtime5 h 6 min

12 V × 100 Ah × 1 × 50% × 85% ÷ 100 W = 5.1 h

Battery bank
1,200 Wh
Usable at the load
510 WhAfter depth of discharge and inverter losses.
Capacity for 8 h
156.9 AhPer battery, with 1 at 12 V.

How the runtime is worked out

The energy the bank can safely give, less what the inverter loses, divided by the load.

Depth of discharge

How much of a battery you can use without shortening its life. Plan on about 50% for lead-acid and 80 to 90% for lithium (LiFePO4).

Inverter efficiency

An inverter turns some of the battery's energy into heat. 85% is typical; a router fed DC straight from the battery skips that loss.

Load

Add up the watts of everything on the UPS: router, switch, radios and ONT. A rated figure is a maximum, so a measured one gives a truer runtime.

Leave headroom

Batteries lose capacity with age, heat and fast discharge. Treat the answer as a best case and size for a longer cut than you expect.